Understanding inflow and infiltration impacts on pumping costs

Inflow and infiltration (I/I) is the unwanted entry of rainwater, stormwater and groundwater into a wastewater sewer. It can occur through cracked pipes, displaced joints, porous manhole walls, defective service connections or downpipes illegally connected to the sewer network. At a pumping station, that clean water has the same hydraulic demand as wastewater, even though it carries few useful solids.

The resulting costs extend beyond a higher electricity bill. Larger and more variable flows can require larger pumps, accelerate wear, reduce hydraulic efficiency and expose downstream facilities to overflow during storms. Low flows can also be expensive when a station repeatedly starts and stops, shortens equipment life or leaves solids settling in a wet well. I/I reduction therefore belongs in both asset management and operating strategy.

Australian conditions make the issue particularly visible. Sydney experiences intense rainfall and flash flooding, Melbourne combines older infrastructure with variable rainfall, and Brisbane and the South East Queensland catchments face prolonged wet periods. Across many cities, roof runoff, paved yards and legacy stormwater connections complicate the boundary between legal drainage and wastewater ingress. Australian utilities therefore face similar hydraulic questions to those examined by LABS of CWEA in Los Angeles, even though rainfall, pipe materials and governance differ.

Utilities in Australia also work within state-based Water Acts, metropolitan Water Management Plans and environmental protection authority licences. For example, Sydney Water’s planning obligations include reducing inflow to its sewage system, while other states use service codes and discharge conditions. The practical challenge is to convert those broad obligations into station-level evidence: which litres are entering, when they arrive and what they cost to pump.

Flow source Typical signal Pumping and network effect Priority response
Rain-derived inflow Rapid rise following rainfall Higher peak flow, shorter pump cycles and greater overflow risk Inspect affected sewers and upstream connections
Groundwater infiltration Persistent base flow and high night flow Continuous energy use and accelerating pipe deterioration Locate defective joints, pipes and manholes
Illegal stormwater entry Flow linked to roofs, yards or surface runoff Unexplained wet-weather demand and capacity loss Survey, educate and enforce disconnection requirements
Normal wastewater flow Stable diurnal pattern linked to population Predictable station demand and operating baseline Use as the control when calculating I/I

The hidden cost inside every litre

At a lift station, the useful question is not simply whether more water costs more to pump. Pump efficiency changes with flow and head, so operators should compare measured kilowatt-hours per megalitre with the pump curve and expected duty. A station operating far outside its efficient envelope can spend disproportionately on energy even before a rain event. Variable-speed drives can improve control, but they do not remove the need to avoid oversizing and excessive cycling.

Wet-weather I/I creates a second cost curve. Flow may rise faster than the installed pumps can convey it, leading to wet-well level alarms, emergency generator use, bypass operations or sewer overflows. The environmental consequence can exceed the metered energy cost, particularly where overflow reporting and public health obligations attract regulatory attention. A modest reduction in peak flow can therefore have a high avoided-cost value.

Low flows deserve attention as well. If pumps start every few minutes to move dilute wastewater, bearings, seals and starters accumulate starts, while short cycles can increase cleaning and odour risks. Good I/I work seeks a stable, efficient baseline rather than simply maximising flow reduction. Technical program news updates can help operators compare local monitoring results with wider industry practice.

Finding the water before it reaches the pump

A defensible business case begins with a baseline. Install flow meters at representative stations, record pump starts, run-time, wet-well levels and rainfall, and separate dry-weather from wet-weather days. Night-time flow can indicate groundwater infiltration, while a sharp response to rainfall suggests stormwater entry. SCADA alarms should distinguish a genuine process problem from a network event arriving upstream of the station.

Physical surveys then turn a pattern into a repair location. Smoke testing can expose leaking joints and illegal connections, CCTV can identify cracks, root intrusion and displaced pipe, while manhole surveys and dye tests can confirm the route. Triage is important because a single large trunk-sewer defect may explain more flow than dozens of minor service issues. Each candidate should have an estimated flow reduction, confidence level and cost.

Education can reduce illegal roof and yard connections without waiting for capital works. For Australian household advice, rain-sensitive design material such as rainwise household guidance can support discussion of where roof water should go and why stormwater should not enter a sewer in a separated network. It complements utility surveys, legal notices and local drainage requirements.

Australian costs, rules and operating realities

Electricity prices, industrial tariffs, pump and electrical contractors, and locally stocked replacement parts shape the savings available. Australian operators commonly use variable-speed drives, remotely monitored lift stations and duty/standby pump arrangements, so energy modelling should include motor efficiency, start frequency and peak demand rather than only nameplate pump power. In remote or flood-prone areas, access, generators and corrosion can make reliability costs as important as kilowatt-hours.

Climate and housing patterns alter the I/I signal. In Melbourne, root intrusion can restrict old pipes and reduce effective capacity; in Sydney, cloudburst rainfall can overwhelm both pipes and pumps; in South East Queensland, saturated soil raises the likelihood of groundwater entering defective infrastructure. Household downpipes connected to old sewers, extensive concrete driveways and sealed front gardens can redirect runoff into the network. These everyday practices mean communication must explain illegal connections clearly, not just publish engineering terminology.

Regulation is fragmented but increasingly specific. New South Wales, Victoria, Queensland and Western Australia each apply different water-service laws, sewer overflow reporting and environmental licence conditions. Sydney Water reports against inflow targets in its Water Management Plan, and metropolitan authorities elsewhere publish overflow or infiltration performance information. Comparing programs therefore requires consistent definitions of I/I, dry-weather flow and cost rather than transferring a target from one jurisdiction to another.

Prioritising repair and operator capability

Projects should be ranked by expected avoided cost and risk, not by the number of defects discovered. A practical metric is net present cost per megalitre removed, combined with the probability of avoiding overflow and the effect on station reliability. A modest trunk-sewer repair may outperform many household subsidies if it removes a persistent peak; conversely, a low-cost local correction may be preferable where overflow consequences are severe.

Operators also need to practise the decisions that accompany inflow events. Training that covers flow interpretation, alarm response and wet-weather operating rules can prevent a routine rise in level from becoming an overflow. A resource on virtual operator training offers a way to rehearse scenarios without taking a critical station offline. Local teams can adapt that approach to Australian rainfall patterns, generator procedures and escalation protocols.

Turning measurements into lower pumping costs

Begin with a clear baseline and a small set of representative stations, then choose methods that fit the available evidence. Flow meters and rainfall data can identify the size of the opportunity; smoke, dye and CCTV surveys can localise it; hydraulic modelling can show how upstream reductions affect downstream capacity. This sequence avoids spending heavily on a visible defect while a larger, less obvious source remains untreated.

Evaluate results with actual operating data. Compare kilowatt-hours, pump starts, wet-well residence time, overflow events and maintenance costs before and after rehabilitation, while allowing for rainfall and population change. If a project reduces water use without reducing I/I, it should not be credited as an I/I project; if it lowers peak flow but shifts operations to another station, the network-wide effect must be captured.

The practical takeaway is to treat every unexplained wet-weather litre as both an operating-cost signal and a potential network defect, then prioritise the source that removes the most costly flow while protecting public health and reliable pump performance.