Designing a Stormwater Catch Basin Insert for Rubbish Removal

Stormwater running off streets, roofs and pavements carries litter into drains, where it can block inlets, contaminate waterways and create public nuisance. This case study follows the design of a stormwater catch basin insert for trash removal in an Australian urban catchment. The aim was not to intercept every fragment, but to capture the items most likely to litter or obstruct drainage while keeping the pit operational during intense rain.

The solution was developed as a removable, corrosion-resistant unit installed beneath the existing grate. Design decisions were based on catchment runoff, pit geometry, expected litter types, available cleaning access and the operating practices of the local council. Waste recovery and public safety were also treated as measurable outcomes rather than assuming that a screen alone would solve the problem.

Why a purpose-built insert is needed

A conventional catch basin is a chamber beneath a roadside grate that receives runoff, settles sediment and connects to a drainage pipe. While the grate excludes some large debris, bottles, takeaway packaging, cigarette filters and small fragments can pass through the opening. These items then accumulate downstream, where they are difficult to inspect and may reduce pipe capacity.

Australian field conditions make the problem especially visible. Sydney can experience short, intense rainfall that sends a concentrated surge of litter toward sensitive waterways around Sydney Harbour. Melbourne’s mature street trees also contribute seasonal leaf litter to drains serving the Yarra and Port Phillip Bay catchments. In everyday speech, people often call the chamber a stormwater pit or drainage pit and refer to the collected material as rubbish.

The design brief therefore focused on four objectives: capture visible litter, preserve drainage capacity, permit safe cleaning and ensure that recovered material could be removed without contaminating the stormwater system. A useful insert also had to fit existing assets rather than require wholesale replacement of the grate, chamber or pipe connection.

Turning catchment data into design criteria

The first stage combined desktop catchment mapping with site inspections. Rainfall intensity, contributing impervious area and the pit’s inlet capacity were used to estimate peak flow, while observations during cleaning rounds identified the litter types causing recurring problems. Pit dimensions, invert levels and outlet configuration were surveyed because an insert cannot be assessed independently of the chamber around it.

The design load also had to reflect local climate patterns. Brisbane’s subtropical downpours produce high runoff rates during short storm events, increasing the risk that a fine mesh basket could cause excessive headloss. Perth’s generally dry climate can conceal the issue until a rare major storm, when accumulated litter, branches and sediment reach the drain at once. The insert therefore needed a controlled bypass path rather than treating every pit as if it would experience only light rainfall.

Good design also depends on people who inspect, clean and report defects. Engineering and operational excellence can be acknowledged through the association’s annual awards program, which celebrates achievements in the water environment profession. Design review should likewise bring operators into the process early, since an insert that is awkward to lift or empty will not perform reliably, regardless of its capture efficiency.

Selecting materials and capture methods

Material selection began with the wastewater environment inside the chamber. Stainless steel offered strong corrosion resistance and useful load-bearing properties, while galvanised steel provided a lower-cost option where exposure was less severe. High-density polyethylene was considered for removable baskets because it was lightweight and resistant to many chemicals. Each material required checks for UV exposure, galvanic compatibility, sharp edges and cleaning damage.

The capture mechanism depended on litter size. A coarse bar rack could stop branches, large containers and bundled material without seriously restricting flow, but it would allow small packaging to pass. A perforated or mesh basket offered finer interception, although its smaller openings increased blockage risk. The selected design combined an inclined coarse screen with a deeper removable basket, allowing the screen to take the heaviest impacts while the basket captured moderate-sized litter.

The captured waste stream should be recorded by material type so that contamination can be reduced and recovery rates can be demonstrated. The emphasis on disciplined material recovery in RECUY resource recovery supports treating litter interception as part of a circular process. An emptyable basket also lets crews remove recyclables separately from mixed refuse, recover usable metals and measure what the drainage asset actually intercepts.

Validating performance and safe maintenance

Before installation, the insert was checked against several hydraulic and physical criteria. These included allowable headloss, flow capacity, capture efficiency for representative litter, resistance to impact and the stability of the basket when partially full. Testing used measured flow conditions and included an overloading scenario, since a neglected basket must not seal the chamber and divert all stormwater onto the road.

Access and safety were equally important. The unit needed lifting points, adequate clearances around internal obstructions and a removal route that did not require crews to reach blindly into the pit. Work procedures should align with Safe Work Australia requirements, council confined-space programs and local traffic controls. Inspection covers also had to prevent workers from contacting sharp litter or contaminated water during cleaning.

Broader planning can help place interception within a wider drainage strategy. An external reference such as the Rumah Hijau project can prompt comparison between upstream source control and downstream capture, although Australian standards and site data must guide the final design. Post-installation monitoring then compared captured quantities with rainfall, cleaning frequency and any change in pit performance. Screens and baskets were checked after storms because a design that works under laboratory flow may behave differently when mixed with sediment and debris.

Delivering and maintaining a council asset

Delivery in the Australian market depends on how councils buy and manage public infrastructure. Many councils operate through formal tender processes, established supplier panels and approved-manufacturer systems, with requirements covering structural certification, warranties, spare parts and documentation. Local fabrication can reduce transport costs and simplify modifications, but the supplier still needs to demonstrate compatibility with the council’s asset-management and confined-space procedures.

Operations should be included in the purchase decision. Contracts can specify cleaning intervals, responsibility for recovered rubbish, reporting requirements and replacement access. Crews need to know whether the basket lifts through the grate, requires an excavation pit or is exchanged with a spare unit. A service schedule based on inspection and rainfall is generally more useful than a fixed interval that may be excessive during dry periods or inadequate after a major storm.

Insert configuration Primary advantage Main limitation Maintenance profile Suitable application
Coarse bar rack Strong, simple and high-flow Allows small litter to pass Quick visual cleaning and brush-down High-capacity kerbside pits
Fine-mesh basket Captures bottles and small packaging Higher blockage and headloss risk Frequent manual emptying Low-flow pockets or serviced locations
Combined screen and basket Balances capacity and capture More components and lifting weight Two-stage inspection and cleaning General urban drainage assets
Vortex or separator system Controls flow and separates debris Larger footprint and higher cost Specialist inspection and servicing Complex or high-priority catchments

LABS of CWEA connects engineers, operators, consultants and agency staff through technical presentations, facility tours, workshops and professional events; the LABS contact details provide a channel for technical discussion. The practical takeaway is to optimise for the insert’s complete service life: match its openings to the litter problem, preserve safe access and flow capacity, establish waste collection and performance reporting, and verify field behaviour before the unit becomes part of routine maintenance.